Medidas para la altura de tomas de agua de la ducha

Measurements for the height of shower water inlets

A mistake in measurements when doing any household chore can lead to problems. If you're a home improvement expert, you surely remember your first botched jobs and the mistakes you probably made early on.

A clear example is when you have to install a shower. In this case, carefully controlling the measurements for the height of the shower's water inlets is key to ensuring its functionality. An error in the measurements can cause the water to fall in an awkward position or make it difficult to access the faucet.

At Brikum , we're always ready to help you with your household chores, gardening, and repairs. That's why, in this article, we'll cover the recommended measurements, the factors that influence installation, and some tips to avoid common mistakes.

Importance of correct installation

Taking accurate shower height measurements not only improves the shower experience but also prevents long-term problems. A poorly calculated installation can cause daily discomfort, difficulty accessing controls, or even leaks due to a poor connection to the faucet.

Furthermore, if the measurements don't follow a standard, any future changes to bathroom fixtures could be complicated.

When defining the measurements for the height of water inlets for the shower, the type of installation, the height of the users and the faucet model must be taken into account. that is going to be placed.

Factors to consider before installation

When taking measurements for the height of shower outlets and before installing them, it is essential to consider various factors that can influence their height and layout.

Shower type

The bathroom 's design directly influences the height of the shower's water inlets. Installing a built-in shower faucet is not the same as installing one with exposed pipes or a prefabricated shower column .

Each model has different specifications, and it's important to follow them to avoid compatibility issues.

Regulations and recommendations

Although there is no single universal regulation, many building codes establish standard measurements for the height of shower outlets to facilitate the installation of shower outlets.

Following these recommendations ensures comfort for most users and makes it easy to replace the faucet in the future without having to modify the installation.

User type

Not everyone has the same needs, and this is reflected in the variability in shower height measurements, as each home is different.

In homes with children, elderly people, or people with reduced mobility, the height of the water inlets can be adjusted to improve accessibility.

In adapted showers, it is also recommended to place the controls at a lower height for ease of use.

Recommended measurements for the height of water inlets in the shower

Although shower outlet height measurements may vary depending on the type of installation, there are certain standard measurements that generally apply in most cases.

Standard height of water intakes

For a conventional shower, the measurements for the height of the water inlets for both hot and cold showers are usually placed at a height of 70 to 120 cm from the floor , depending on the type of faucet and the design of the bathroom.

This height allows easy access to the controls without having to bend or stretch too far.

Recommended height for the fixed shower head

If the shower has a fixed shower head on the wall, the measurements for the height of the shower inlets and outlets should be between 190 and 210 cm , depending on the height of the users.

This ensures that the water falls comfortably over your head without any uncomfortable splashing.

Height for handheld shower

In showers with handheld showerheads, the recommended height measurements for shower water inlets are usually between 75 and 110 cm .

In this case, it is important to consider the wall mount, which should be placed at a suitable height for use without having to bend down.

Distance between hot and cold water outlets

For proper faucet installation, the hot and cold water inlets must be separated by 12 to 15 cm .

This is one of the key shower outlet height measurements to ensure the mixer fits properly without additional adjustments.

Variations depending on the type of installation

Not all spaces have the same design, and this can influence the measurements for the height of shower outlets.

Built-in shower vs. shower with exposed pipes

Built-in showers require more precise planning, as they are installed inside the wall and any subsequent modifications are complicated. Showers with exposed plumbing, on the other hand, allow for greater flexibility in the placement of the plumbing fixtures.

Height in rain showers

If a rain shower is installed on the ceiling, the water inlet should be located at the top of the wall or on the ceiling itself, ensuring that the water flow is even and covers the entire shower area.

Measurements in built-in showers

Built-in bathrooms allow for greater customization of shower outlet heights, adapting them to the user's needs. In these cases, it's advisable to conduct preliminary tests before finalizing the installation.

Common installation mistakes and how to avoid them

Making mistakes when measuring the height of shower outlets can lead to long-term problems.

  • Outlets too low or high : To avoid placing them at an inappropriate height, it is advisable to measure carefully and test different heights before installation.
  • Incorrect distance between hot and cold water : To avoid this, it is recommended to use an installation template.
  • Misalignment with the taps : It is important to use a level before fixing the taps.

With all these recommendations, you'll see how taking measurements for the height of shower water inlets and subsequent installation will be a piece of cake.



Back to blog